Chinese Journal of Medical Ultrasound (Electronic Edition) >
2016 , Vol. 13 >Issue 03: 191 - 197
DOI: https://doi.org/10.3877/cma.j.issn.1672-6448.2016.03.006
A comparative study on modified right heart contrast echocardiography and traditional right heart contrast echocardiography
Received date: 2015-06-26
Online published: 2016-03-01
To compare the safety, stability and effectiveness of modified right heart contrast echocardiography and traditional right heart contrast echocardiography in detection of intra- or extra-cardiac right to left shunt (RLS).
(1) Microscopic analysis: After agitating 10 times or 20 times (AS10, AS20, ASb10, ASb20), two right heart contrast agent (modified: 8 ml saline+ 1 ml blood+ 1 ml air; traditional: 9 ml saline+ 1 ml air) underwent the microscopic examination to compare the bubble size, bubble number and red blood cell morphology; (2) Clinical experiment: Thirty-two inpatients or outpatients suspected of RLS (cryptogenic stroke, transient ischemic attack, migraine with aura or platypnea-orthodeoxia syndrome) in Sichuan Provincial Hospital were selected. All patients underwent two right heart contrast echocardiography in which contrast agents had been agitated for 10 and 20 times (AS10, AS20, ASb10, ASb20). Monitor the right heart developing time, RLS and the oxygen saturation change were monitored and the RLS were semi-quantitatively analyzed. The indirect bilirubin and urobilinogen change after the contrast echocardiography were compared.
Microscopic analysis showed that red blood cell membrane damaged more seriously as the agitated times increased. ASb20 generated more bubbles and the number of bubbles was about 4 times of that of AS10 generated (t=14.180, P<0.01); but the bubble size difference was not significant. With the modified method, RLS were detected in 22 patients (68.8%, 22/32). With the traditional method, RLS were detected in 18 patients (56.3%, 18/32). The results of semi-quantitative analysis of RLS was significant different between any two groups (ASb20 vs. AS10, AS20, ASb10: χ2=13.567, 11.646 and 9.001, respectively; ASb10 vs. AS10, AS20: χ2=9.125 and 2.589; AS20 vs. AS10: χ2= 8.127; all P<0.01). The change of oxygen saturation, the indirect bilirubin and urobilinogen were not significant after the contrast echocardiography.
Modified right heart contrast echocardiography is a safe, stable and cost-effective method to detect RLS. The semi-quantitative analysis of RLS with modified right heart contrast echocardiography and their relationship with clinical accident needs further research.
Yi Wang , Jie Zeng , Wenhua Li , Yan Deng , Chunmei Li , Lixue Yin . A comparative study on modified right heart contrast echocardiography and traditional right heart contrast echocardiography[J]. Chinese Journal of Medical Ultrasound (Electronic Edition), 2016 , 13(03) : 191 -197 . DOI: 10.3877/cma.j.issn.1672-6448.2016.03.006
[1] | Meissner I Khandheria BK, Heit JA, et al. Patent foramen ovale: innocent or guilty? Evidence from a prospective population-based study [J]. J Am Coll Cardiol, 2006, 47(2): 440-445. |
[2] | Dowson A, Mullen MJ, Peatfield R, et al. Migraine Intervention With STARFlex Technology (MIST) trial: a prospective, multicenter, double-blind, sham-controlled trial to evaluate the effectiveness of patent foramen ovale closure with STARFlex septal repair implant to resolve refractory migraine headache [J]. Circulation, 2008, 117(11): 1397-1404. |
[3] | de Belder MA, Tourikis L, Leech G, et al. Risk of patent foramen ovale for thromboembolic events in all age groups [J]. Am J Cardiol, 1992, 69(16): 1316-1320. |
[4] | Cabanes L, Mas JL, Cohen A, et al. Atrial septal aneurysm and patent foramen ovale as risk factors for cryptogenic stroke in patients less than 55 years of age. A study using transesophageal echocardiography [J]. Stroke, 1993, 24(12): 1865-1873. |
[5] | Sastry S, Daly K, Chengodu T, et al. Is transcranial Doppler for the detection of venous-to-arterial circulation shunts reproducible? [J]. Cerebrovasc Dis, 2007, 23(5-6): 424-429. |
[6] | Lange MC, Zetola VF, Piovesan EJ, et al. Saline versus saline with blood as a contrast agent for right-to-left shunt diagnosis by transcranial Doppler: is there a significant difference? [J]. J Neuroimaging, 2012, 22(1): 17-20. |
[7] | Martinez-Sanchez P, Medina-Baez J, Lara-Lara M, et al. Low sensitivity of the echocardiograph compared with contrast transcranial Doppler in right-to-left shunt [J]. Neurologia, 2012, 27(2): 61-67. |
[8] | Droste DW, Lakemeier S, Wichter T, et al. Optimizing the technique of contrast transcranial Doppler ultrasound in the detection of right-to-left shunts [J]. Stroke, 2002, 33(9): 2211-2216. |
[9] | Fan S, Nagai T, Luo H, et al. Superiority of the combination of blood and agitated saline for routine contrast enhancement [J]. J Am Soc Echocardiogr, 1999, 12(2): 94-98. |
[10] | Marriott K, Manins V, Forshaw A, et al. Detection of right-to-left atrial communication using agitated saline contrast imaging: experience with 1 162 patients and recommendations for echocardiography [J]. J Am Soc Echocardiogr, 2013, 26(1): 96-102. |
[11] | Vallurupalli S, Lodha A, Kupfer Y, et al. Platypnea-Orthodeoxia syndrome after repair of a paraesophageal hernia [J]. BMJ Case Rep, 2013. |
[12] | Choi DY, Shin DH, Cho KH, et al. Migraine with aura: a predictor of patent foramen ovale in children and adolescents [J]. Cephalalgia, 2013, 33(7): 463-468. |
[13] | Takagi H, Umemoto T; ALICE (All-Literature Investigation of Cardiovascular Evidence) Group. A meta-analysis of case-control studies of the association of migraine and patent foramen ovale [J]. J Cardiol, 2015. [Epub ahead of print] |
[14] | Homma S, Sacco RL, Di Tullio MR, et al. Effect of medical treatment in stroke patients with patent foramen ovale: patent foramen ovale in Cryptogenic Stroke Study [J]. Circulation, 2002, 105(22): 2625-2631. |
[15] | Kernan WN, Ovbiagele B, Black HR, et al. Guidelines for the prevention of stroke in patients with stroke and transient ischemic attack: a guideline for healthcare professionals from the American Heart Association/American Stroke Association [J]. Stroke, 2014, 45(7): 2160-2236. |
[16] | 中国医师协会心血管内科医师分会. 卵圆孔未闭处理策略中国专家建议 [J]. 心脏杂志, 2015, 4: 372-379. |
[17] | 李越, 刘若卓, 翟亚楠, 等. 健康志愿者右心声学造影结果的初步分析 [J/CD]. 中华医学超声杂志:电子版, 2014, 11(2): 135-141. |
[18] | Zhao E, Wei Y, Zhang Y, et al. A Comparison of Transthroracic Echocardiograpy and Transcranial Doppler With Contrast Agent for Detection of Patent Foramen Ovale With or Without the Valsalva Maneuver [J]. Medicine (Baltimore), 2015, 94(43): e1937. |
/
〈 |
|
〉 |
Copyright © Chinese Journal of Medical Ultrasound (Electronic Edition), All Rights Reserved. Tel: 010-51322630、2632、2628 Fax: 010-51322630 E-mail: csbjb@cma.org.cn Powered by Beijing Magtech Co. Ltd |