Chinese Journal of Medical Ultrasound (Electronic Edition) >
2020 , Vol. 17 >Issue 07: 638 - 643
DOI: https://doi.org/10.3877/cma.j.issn.1672-6448.2020.07.010
Effect of quality control circle activity in improving coincidence rate of neonatal biliary atresia diagnosed by ultrasound
Received date: 2020-05-09
Online published: 2020-07-01
To investigate the effect of quality control circle (QCC) activity in improving the coincidence rate of neonatal biliary atresia diagnosed by ultrasound.
The QCC activity was carried out from April 2019 to November 2019. By determining the theme of the activity and drawing up the plan and taking the results of operation or cholangiography as the standard, a retrospective analysis was performed on the coincidence rate of ultrasonic diagnosis and reasons of missed diagnosis and misdiagnosis based on 283 patients who underwent neonatal biliary atresia screening at the Department of Ultrasonic diagnosis of Guangdong Maternal and Child Health Hospital from April 2018 to November 2018. Based on the data, the goal and the measures were determined, confirmed, and implemented continuously from April to November 2019. The coincidence rate of ultrasonic diagnosis before the implementation of the measures (from April to November 2018) was compared with that after the implementation of the measures (from April to November 2019).
After the QCC activity, it was found that the number of cases who had pathology or cholangiography report and underwent ultrasound was 35, of which 27 had consistent diagnoses by ultrasound and by pathology or cholangiography, and the coincidence rate of ultrasonic diagnosis of biliary atresia was 77%. The coincidence rate of ultrasonic diagnosis of neonatal biliary atresia increased from 43% to 77% after implementing the QCC activity, and the difference was statistically significant (P<0.05).
The QCC activity can effectively improve the coincidence rate of ultrasonic diagnosis of neonatal biliary atresia and improve the professional quality management ability of ultrasonic medicine.
Key words: Quality control; Quality control circle; Biliary atresia; Ultrasonography
Limin Wang , Ling Xu , Lian Jian , Yunxiang Pan , Ning Shang . Effect of quality control circle activity in improving coincidence rate of neonatal biliary atresia diagnosed by ultrasound[J]. Chinese Journal of Medical Ultrasound (Electronic Edition), 2020 , 17(07) : 638 -643 . DOI: 10.3877/cma.j.issn.1672-6448.2020.07.010
| 1 | 中华医学会小儿外科学分会肝胆外科学组,中国医师协会器官移植医师分会儿童器官移植学组. 胆道闭锁诊断及治疗指南(2018版) [J]. 中华小儿外科杂志, 2019, 40(5): 392-398. |
| 2 | Hartley JL, Davenport M, Kelly DA. Biliary atre-sia [J]. Lancet, 2009, 374(9702): 1704-1713. |
| 3 | Yoon PW, Bresee JS, Olney RS, et al. Epidemiology of biliary atresia: A population-based study [J]. Pediatrics, 1997, 99(3): 376-382. |
| 4 | Mashima M, Tanaka H, Numoto A, et al. Antenatal three-dimensional sonographie features of fetal biliary atresia [J]. J Med Ultrasonics, 2013, 40(3): 279-281. |
| 5 | 付晓燕,张萍,刘利青, 等. 品管圈对提升门诊预约诊疗服务的探讨 [J]. 医院管理论坛, 2014, 31(2): 29-31. |
| 6 | 李兴川,陈志美,李仁兰, 等. 应用品管圈降低新生儿住院期间安全隐患发生率的临床研究 [J]. 重庆医学, 2019, 48(3): 512-514, 518. |
| 7 | 陈卫琴,周凯云,陆英, 等. 品管圈活动对神经外科住院患者健康行为及自我效能的影响 [J]. 重庆医学, 2017, 46(26): 3736-3737. |
| 8 | |
| 9 | 国家卫生和计划生育委员会. 2016年国家医疗服务与质量安全报告 [M]. 北京: 人民卫生出版社, 2017. |
| 10 | 国家超声医学质量控制中心. 超声医学专业质量管理控制指标专家共识(2018年版) [J]. 中华超声影像学杂志, 2018, 27(11): 921-92. |
| 11 | 刘娜娜,李鑫,詹江华. 胆道闭锁超声诊断的研究进展 [J]. 大理大学学报, 2020, 5(2): 17-22. |
| 12 | Humphrey TM, Stringer MD. Biliary atresia: US diagnosis [J]. Radiology, 2007, 244(3): 845-851. |
| 13 | 徐魏军,裴广华,王世城, 等. 胆道闭锁超声评分量化诊断研究 [J]. 中国超声医学杂志, 2019, 35(8): 716-719. |
| 14 | Tan Kendrick AP, Phua KB, Ooi BC, et al. Biliary Atresia: Making the Diagnosis by the Gallbladder Ghost Triad [J]. Pediatr Radiol, 2003, 33(5): 311-315. |
/
| 〈 |
|
〉 |
|
Copyright © Chinese Journal of Medical Ultrasound (Electronic Edition), All Rights Reserved. Tel: 010-51322630、2632、2628 Fax: 010-51322630 E-mail: csbjb@cma.org.cn Powered by Beijing Magtech Co. Ltd |