切换至 "中华医学电子期刊资源库"

中华医学超声杂志(电子版) ›› 2022, Vol. 19 ›› Issue (09) : 1008 -1012. doi: 10.3877/cma.j.issn.1672-6448.2022.09.024

综述

多模态影像学诊断卵圆孔未闭的临床现状及研究进展
宋弯弯1, 白姣1,()   
  1. 1. 430060 武汉,武汉大学中南医院心血管超声医学科
  • 收稿日期:2020-12-15 出版日期:2022-09-01
  • 通信作者: 白姣
  • 基金资助:
    武汉大学中南医院医学科技创新平台支撑项目(面上项目)(PTXM2021008)

Current status and research progress of multimodal imaging in clinical diagnosis of patent foramen ovale

Wanwan Song1, Jiao Bai1()   

  • Received:2020-12-15 Published:2022-09-01
  • Corresponding author: Jiao Bai
引用本文:

宋弯弯, 白姣. 多模态影像学诊断卵圆孔未闭的临床现状及研究进展[J]. 中华医学超声杂志(电子版), 2022, 19(09): 1008-1012.

Wanwan Song, Jiao Bai. Current status and research progress of multimodal imaging in clinical diagnosis of patent foramen ovale[J]. Chinese Journal of Medical Ultrasound (Electronic Edition), 2022, 19(09): 1008-1012.

1
Calvert PA, Rana BS, Kydd AC, et al. Patent foramen ovale: anatomy, outcomes, and closure [J]. Nat Rev Cardiol, 2011, 8(3): 148-160.
2
Lange M. PFO closure and stroke [J]. Dtsch Arztebl Int, 2018, 115(4): 56-57.
3
Dao CN, Tobis JM. PFO and paradoxical embolism producing events other than stroke [J]. Catheter Cardiovasc Interv, 2011, 77(6): 903-909.
4
Arquizan C, Coste J, Touboul PJ, et al. Is patent foramen ovale a family trait? A transcranial Doppler sonographic study [J]. Stroke, 2001, 32(7): 1563-1566.
5
Silvestry FE, Cohen MS, Armsby LB, et al. Guidelines for the echocardiographic assessment of atrial septal defect and patent foramen ovale: from the American Society of Echocardiography and Society for Cardiac Angiography and Interventions [J]. J Am Soc Echocardiogr, 2015, 28(8): 910-958.
6
Bartel T, Müller S. Device closure of interatrial communications: peri-interventional echocardiographic assessment [J]. Eur Heart J Cardiovasc Imaging, 2013, 14(7): 618-624.
7
Hagen PT, Scholz DG, Edwards WD. Incidence and size of patent foramen ovale during the first 10 decades of life: an autopsy study of 965 normal hearts [J]. Mayo Clin Proc, 1984, 59(1): 17-20.
8
Bayar N, Arslan Ş, Çağırcı G, et al. Assessment of morphology of patent foramen ovale with transesophageal echocardiography in symptomatic and asymptomatic patients [J]. J Stroke Cerebrovasc Dis, 2015, 24(6): 1282-1286.
9
Komar M, Podolec P, Przewłocki T, et al. Transoesophageal echocardiography can help distinguish between patients with "symptomatic" and "asymptomatic" patent foramen ovale [J]. Kardiol Pol, 2012, 70(12): 1258-1263.
10
Nakayama R, Takaya Y, Akagi T, et al. Identification of high-risk patent foramen ovale associated with cryptogenic stroke: development of a scoring system [J]. J Am Soc Echocardiogr, 2019, 32(7): 811-816.
11
Holda MK, Koziej M. Morphometric features of patent foramen ovale as a risk factor of cerebrovascular accidents: a systematic review and meta-analysis [J]. Cerebrovasc Dis, 2020, 49(1): 1-9.
12
Pristipino C, Sievert H, D'Ascenzo F, et al. European position paper on the management of patients with patent foramen ovale. General approach and left circulation thromboembolism [J]. Eur Heart J, 2019, 40(38): 3182-3195.
13
Spencer MP, Moehring MA, Jesurum J, et al. Power m-mode transcranial Doppler for diagnosis of patent foramen ovale and assessing transcatheter closure [J] Neuroimaging, 2004, 14(4): 342-349.
14
Lao AY, Sharma VK, Tsivgoulis G, et al. Detection of right-to-left shunts: comparison between the International Consensus and Spencer Logarithmic Scale criteria [J]. J Neuroimaging, 2008, 18(4): 402-406.
15
Mojadidi MK, Roberts SC, Winoker JS, et al. Accuracy of transcranial Doppler for the diagnosis of intracardiac right-to-left shunt: a bivariate meta-analysis of prospective studies [J]. JACC Cardiovasc Imaging, 2014, 7(3): 236-250.
16
Koutroulou I, Tsivgoulis G, Tsalikakis D, et al. Epidemiology of patent foramen ovale in general population and in stroke patients: a narrative review [J]. Front Neurol, 2020, 11: 281.
17
Droste DW, Lakemeier S, Wichter T, et al. Optimizing the techniques of contrast transcranial doppler ultrasound in the detection of right-to-left shunts [J]. Stroke, 2002, 33(9): 2211-2216.
18
Zhao E, Du Y, Xie H, et al. Modified method of contrast transthoracic echocardiography for the diagnosis of patent foramen ovale [J]. BioMed Res Int, 2019, 2019: 9828539.
19
Mojadidi MK, Winoker JS, Roberts SC, et al. Accuracy of conventional transthoracic echocardiography for the diagnosis of intracardiac right-to-left shunt: a meta-analysis of prospective studies [J]. Echocardiography, 2014, 31(9): 1036-1048.
20
Figueroa CA, Bertazzo BB, Gonzalez GJ, et al. Effectiveness of transthoracic echocardiogram in patent foramen ovale diagnosis. Systematic review of last ten years [J]. Rev Fac Cien Med Univ Nac Cordoba, 2019, 76(4): 211-216.
21
Takaya Y, Watanabe N, Ikeda M, et al. Importance of abdominal compression valsalva maneuver and microbubble grading in contrast transthoracic echocardiography for detecting patent foramen ovale [J]. J Am Soc Echocardiogr, 2020, 33(2): 201-206.
22
Schneider B, Zienkiewicz T, Jansen V, et al. Diagnosis of patent foramen ovale by transesophageal echocardiography and correlation with autopsy findings [J]. Am J Cardiol, 1996, 77(14): 1202-1209.
23
王一茹, 邓玉姣, 阳开秀, 等. 卵圆孔未闭经胸超声心动图声学造影及经食管超声心动图的单中心诊断数据分析 [J/OL]. 中华医学超声杂志(电子版), 2020, 17(6): 546-551.
24
Rodrigues AC, Picard MH, Carbone A, et al. Importance of adequately performed valsalva maneuver to detect patent foramen ovale during transesophageal echocardiography [J]. J Am Soc Echocardiogr, 2013, 26(11): 1337-1343.
25
Al SR, Michele SD, Kinsara AJ, et al. Contrast transesophageal three dimensional echocardiographic imaging for patent foramen ovale: a needful role? [J]. Monaldi Arch Chest Dis, 2020, 90(4): 1278.
26
Marriott K, Manins V, Forshaw A, et al. Detection of right-to-left atrial communication using agitated saline contrast imaging: experience with 1162 patients and recommendations for echocardiography [J]. J Am Soc Echocardiogr, 2013, 26(1): 96-102.
27
Moon J, Park Y, Park SJ, et al. Comparison of intracardiac echocardiography and transesophageal echocardiography for image guidance in percutaneous patent foramen ovale closure [J]. Medicina, 2020, 56(8): 401.
28
Yang X, Wang H, Wei Y, et al. Diagnosis of patent foramen ovale: the combination of contrast transcranial Doppler, contrast transthoracic echocardiography, and contrast transesophageal echocardiography [J]. Biomed Res Int, 2020, 2020: 8701759.
29
Koh TW. When to use femoral vein injection for diagnosis of patent foramen ovale-Effect of a persistent eustachian valve on right atrial flow patterns during contrast transesophageal echocardiography [J]. Echocardiography, 2017, 34(5): 768-772.
30
Gevorgyan R, Perlowski A, Shenoda M, et al. Sensitivity of brachial versus femoral vein injection of agitated saline to detect right-to-left shunts with transcranial Doppler [J]. Catheter Cardiovasc Interv, 2014, 84(6): 992-996.
31
Williamson EE, Kirsch J, Araoz PA, et al. ECG-gated cardiac CT angiography using 64-MDCT for detection of patent foramen ovale [J]. AJR Am J Roentgenol, 2008, 190(4): 929-933.
32
Purvis JA, Morgan DR, Hughes SM. Prevalence of patent foramen ovale in a consecutive cohort of 261 patients undergoing routine "coronary" 64-multi-detector cardiac computed tomography [J]. Ulster Med J, 2011, 80(2): 72-75.
33
Kara K, Sivrioğlu AK, Öztürk E, et al. The role of coronary CT angiography in diagnosis of patent foramen ovale [J]. Diagn Interv Radiol, 2016, 22(4): 341-346.
34
Kosehan D, Akin K, Koktener A, et al. Interatrial shunt: diagnosis of patent foramen ovale and atrial septal defect with 64 row coronary computed tomography angiography [J]. Jpn J Radiol, 2011, 29(8): 576-582.
35
Andreis A, Agnoletti G, Scacciatella P. Incidental diagnosis of four pulmonary arteriovenous fistulas during patent foramen ovale closure: a case report [J]. Cardiol Young, 2020, 30(9): 1363-1365.
36
Lembcke A, Grubitzsch H, Hein PA. Pulmonary embolism and thrombus-in-transit crossing a patent foramen ovale: comprehensive diagnosis using cardiac multislice computed tomography [J]. Eur J Cardiothorac Surg, 2016, 49(1): 356.
37
Mohrs OK, Petersen SE, Erkapic D, et al. Diagnosis of patent foramen ovale using contrast-enhanced dynamic MRI: a pilot study [J]. AJR Am J Roentgenol, 2005, 184(1): 234-240.
38
Nusser T, Hoher M, Merkle N, et al. Cardiac magnetic resonance imaging and transesophageal echocardiography in patients with transcatheter closure of patent foramen ovale [J]. J Am Coll Cardiol, 2006, 48(2): 322-329.
39
Hamilton-Craig C, Sestito A, Natale L, et al. Contrast transoesophageal echocardiography remains superior to contrast-enhanced cardiac magnetic resonance imaging for the diagnosis of patent foramen ovale [J]. Eur J Echocardiogr, 2011, 12(3): 222-227.
40
Parikh JD, Kakarla J, Keavney B, et al. 4D flow MRI assessment of right atrial flow patterns in the normal heart - influence of caval vein arrangement and implications for the patent foramen ovale [J]. PLoS One, 2017, 12(3): e173046.
41
Kakarla J, Coats L, Parikh JD, et al. Platydeoxia orthopnoea-revisiting a rare clinical phenomenon with a novel imaging modality [J]. Heart, 2014, 100: A69.
42
Miller DD. Machine intelligence in cardiovascular medicine [J]. Cardiol Rev, 2020, 28(2): 53-64.
No related articles found!
阅读次数
全文


摘要