Feasibility research of preoperative evaluation of neoplastic microvascular morphology in hepatocellular carcinoma patients using contrast-enhanced ultrasound

Qingguang Lin1, Ruhai Zou1, Jianwei Wang1, Feng Han1, Xiaoqing Pei1, Anhua Li1,()   

  1. 1. Department of Ultrasound, Sun Yat-sen University Cancer Center, National Key Laboratory of Oncology in Southern China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, 510060, China
  • Received:2014-09-27 Online:2015-06-01 Published:2015-06-01
  • Contact: Anhua Li
  • About author:
    Corresponding author:Li Anhua, Email:

Abstract:

Objective

To explore the feasibility of contrast-enhanced ultrasonograhy (CEUS) in preoperative classification of hepatocellular carcinoma (HCC) microvascular morphology.

Methods

Totally 94 HCC patients who underwent CEUS were analyzed retrospectively. And the offline time-intensity curve (TIC) were drawn using SonoTumor. The tumor size, alpha fetoprotein (AFP), cirrhosis, Child-Pugh classification, tumor differentiation and TNM stage were statistically analyzed. The intratumoral microvessels of HCC in 94 cases were evaluated by CD34 immunohistochemical staining. The relationship between intratumoral microvessel morphology and CEUS parameters were analyzed.

Results

CD34 immunohistochemical staining showed three distinct microvessel types in 94 cases of HCC: 28 cases of capillary-like type, 14 cases of sinusoid-like type and 52 cases of mixed type. There were no significant differences of clinical data among three microvascular morphology types. The parameters of peak strength (PE), rise time (RT), wash-in rate (WiR), wash-in perfusion index (WiPI), wash-in area under the curve (WiAUC) and mean transit time (MTT) in 28 cases of capillary-like type were (4 350.7±2 566.0) a.u, (10.7±3.2) s, (717.0±489.9) a.u, (12 820.3±8 331.6) a.u, (128 240.8±74 487.1) a.u, (71.9±33.1) s. Those parameters in 14 cases of sinusoid-like type were (2 471.6±1 107.1) a.u, (16.2±4.2) s, (321.9±171) a.u, (5 561.4±2 938.0) a.u, (86 780.1±47 563.7) a.u, (117.8±69.6) s. And in 52 cases of mixed type they were (3 563.2±2 343.1) a.u, (14.1±4.8) s, (519.4±403.2) a.u, (9 015.3±6 884.7) a.u, (110 208.4±77 511.3) a.u, (107.5±88.2) s respectively. The CEUS parameters of WiR, WiPI in capillary-like type HCC patients were higher than sinusoid-like type and mixed type HCC patients, while RT was lower than sinusoid-like type and mixed type HCC patients, and the differences were significant (WiR: t=3.87, 3.3, both P=0.05; WiPI: t=2.96, 2.06, both P=0.05; RT: t=3.19, 2.34, both P=0.05). The parameter of PE in capillary-like type HCC patients were significantly higher than that in sinusoid-like type HCC patients (t=2.51, P=0.05). And the parameter of PE in capillary-like type HCC patients was higher than mixed HCC patients, but there was no significant difference. The parameters of PE, WiR and WiPI in mixed type HCC patients were higher than that in sinusoid-like type HCC patients, while RT in mixed type HCC patients were lower than that in sinusoid-like type HCC patients, but there were no significant differences. No significant differences of WiAUC and MTT were observed in HCC patients with different microvascular morphology.

Conclusions

There were significant differences of CEUS parameters in different microvascular morphology types. And CEUS, as a non-invasive method, can be used for preliminary preoperative prediction of microvascular morphology in HCC patients.

Key words: Carcinoma, Hepatocellular, Microvascular, Ultrasonograhy, Contrast media