Difference of the values of Young′s modulus between the middle part and inferior extremity of renal cortex: an animal study

Na Li1, Xiaona Liu2, Haining Zheng3, Chaoyang Wen4,()   

  1. 1. Department of Ultrasound, Chinese People's Liberation Army General Hospital, Beijing 100853, China; Department of Auxiliary Diagnosis, the 463rd Hospital of Shenyang Military Region, Shenyang 110042, China
    2. Department of Ultrasound, Chinese People's Liberation Army General Hospital, Beijing 100853, China;Department of Ultrasound, Binzhou Medical University Hospital, Binzhou 256603, China
    3. Department of Ultrasound, Peking University International Hospital, Beijing 102206, China
    4. Department of Ultrasound, Chinese People's Liberation Army General Hospital, Beijing 100853, China;Department of Ultrasound, Peking University International Hospital, Beijing 102206, China
  • Received:2018-02-27 Published:2018-04-01
  • Corresponding author: Chaoyang Wen
  • About author:
    Corresponding author: Wen Chaoyang, Email:
引用本文:

李娜, 刘晓娜, 郑海宁, 温朝阳. 肾脏中部及下极皮质杨氏模量值差异的动物实验研究[J]. 中华医学超声杂志(电子版), 2018, 15(04): 309-312.

Na Li, Xiaona Liu, Haining Zheng, Chaoyang Wen. Difference of the values of Young′s modulus between the middle part and inferior extremity of renal cortex: an animal study[J]. Chinese Journal of Medical Ultrasound (Electronic Edition), 2018, 15(04): 309-312.

目的

研究兔肾脏中部与下极皮质杨氏模量值差异。

方法

10只日本大耳白兔,结扎肾静脉,结扎前、结扎后15 min、30 min、60 min、90 min,超声剪切波弹性成像技术检测肾脏中部及下极皮质杨氏模量值。采用独立样本t检验,比较同一时间点肾中部与肾下极杨氏模量值之间的差异;采用单因素方差分析方法,比较同一部位不同时间点杨氏模量值之间的差异。

结果

结扎肾静脉前,肾中部、下极皮质杨氏模量值分别为(15.93±1.70)kPa、(4.66±1.4)kPa,结扎后15 min分别为(34.84±4.91)kPa、(10.95±3.09)kPa,30 min分别为(41.55±3.19)kPa、(20.39±4.06)kPa,60 min分别为(50.63±2.73)kPa、(30.96±4.98)kPa;90 min分别为(56.61±2.96)kPa、(42.40±5.79)kPa。结扎肾静脉前后,肾中部皮质杨氏模量值均显著高于肾下极,差异有统计学意义(t=21.63、7.44、7.19、5.26、2.41,P均<0.05),结扎后各时点两部位的杨氏模量值均显著高于结扎前(t=-3.30、3.38、-2.47、1.83,P均<0.05),且随时间延长逐渐增加(t=-5.31、8.26、-7.81、3.65,P均<0.05)。

结论

超声剪切波弹性成像技术测量的兔肾中部皮质杨氏模量值高于肾下极,提示兔肾脏皮质存在各向异性。结扎兔肾静脉后90 min内,肾脏中部皮质杨氏模量值也高于下极。

Objective

To study the difference of the values of Young's modulus between the middle part and the inferior extremity of rabbit renal cortex.

Methods

Ten Japanese white rabbits were used for this study. The right renal vein was ligated. At time intervals of 15, 30, 60 and 90 minutes after ligation, the values of Young's modulus from different parts of the right renal cortex were recorded. Independent sample t test was used to compare the difference of the values of Young's modulus from the middle part and the inferior extremity of renal cortex at the same time point. Single factor variance analysis was used to compare the values of Young's modulus at the same point at difference time.

Results

Before renal vein ligation, the values of Young's modulus from the middle part and the inferior extremity of renal cortex were (15.93±1.70) kPa and (4.66±1.4) kPa. After the ligation, the values from those two parts of the kidney were as follows: 15 min after ligation, (34.84±4.91) kPa and (10.95±3.09) kPa; 30 min after ligation, (41.55±3.19) kPa and (20.39±4.06) kPa; 60 min after ligation, (50.63±2.73) kPa and (30.96±4.98) kPa; 90 min after ligation, (56.61±2.96) kPa and (42.40±5.79) kPa. The value of Young's modulus from the middle part of renal cortex was significantly higher than the inferior extremity of renal cortex, and the difference was statistically significant (t=21.63, 7.44, 7.19, 5.26 and 2.41, all P<0.05). The values of Young's modulus from different parts of the renal cortex after renal vein ligation were significantly higher than those before the ligation (t=-3.30, 3.38, -2.47, 1.83, all P<0.05), and the values increased gradually with time increased after ligation (t=-5.31, 8.26, -7.81, 3.65, all P<0.05).

Conclusions

The values of Young's modulus from the middle part of renal cortex were higher than those of the inferior extremity of renal cortex determined by shear wave ultrasound elastic imaging technique. It is suggested that there is anisotropy in the renal cortex of rabbit. Prior to and within 90 min following renal vein ligation, the values of Young's modulus from the middle part of renal cortex were higher than those of the inferior extremity of renal cortex determined by shear wave ultrasound elastic imaging technique.

图1 肾脏中部皮质、下极皮质的杨氏模量值测量超声图像
表1 肾静脉结扎前、结扎后15 min、30 min、60 min、90 min后中部肾皮质与下极肾皮质的杨氏模量值比较(kPa,±s
图2 肾静脉结扎60 min后右肾病理图像(HE ×10)
[1]
温朝阳, 范春芝, 安力春, 等. 实时定量超声弹性成像技术检测肱二头肌松弛和紧张状态下杨氏模量值差异[J/CD]. 中华医学超声杂志(电子版), 2011, 8(1): 129-134.
[2]
杨龙, 袁建军, 王绮, 等. 超声弹性成像测量剪切波速度的影响因素[J]. 中国医学影像学杂志, 2014, 22(9): 697-700.
[3]
Goertz RS,Egger C,Neurath MF, et al. Impact of food intake, ultrasound transducer, breathing maneuvers and body position on acoustic radiation force impulse (ARFI) elastometry of the liver[J]. Ultraschall Med, 2012, 33(4): 380-385.
[4]
杨龙, 袁建军, 王绮, 等. 声触诊组织量化技术测量牛离体肝脏剪切波速度的影响因素[J]. 中国医学影像学杂志, 2013, 21(7): 494-496.
[5]
Chang S,Kim MJ,Kim J, et al. Variability of shear wave velocity using different frequencies in acoustic radiation force impulse (ARFI) elastography: a phantom and normal liver study [J]. Ultraschall Med, 2013, 34(3): 260-265.
[6]
汪惠鹏, 王学梅, 刘艳君, 等. 实时二维剪切波弹性成像测量肝脏弹性值的影响因素研究进展[J/CD]. 中华医学超声杂志(电子版), 2016, 13(9): 718-720.
[7]
姜镔, 王学梅, 王云忠, 等. 实时剪切波弹性成像测量胸锁乳突肌杨氏模量时声束平面与肌束不同角度对测量值的影响[J]. 中国医学影像学杂志, 2014, 30(2): 269-272.
[8]
张隽, 邓又斌, 黄媛, 等. 探头扫查平面与肌纤维走行方向夹角对剪切波传播速度的影响[J]. 中国医学影像学杂志, 2013, 29(9): 1497-1499.
[9]
郭乐杭, 徐辉雄, 付慧君, 等. 声触诊组织定量技术取样部位及探头扫查对肾脏弹性的测值的影响[J/CD]. 临床超声医学杂志(电子版), 2013, 15(1): 13-15.
[10]
Gao J,Zheng X,Zheng YY, et al. Shear Wave Elastography of the Spleen for Monitoring Transjugular Intrahepatic Portosystemic Shunt Function: A Pilot Study[J]. J Ultrasound Med, 2016, 35(5): 951-958.
[11]
王海燕. 肾脏病学 [M]. 3版. 北京: 人民卫生出版社, 2008: 257-262.
[12]
刘晓娜, 李娜, 温朝阳, 超声弹性成像技术在深静脉血栓分期中应用的研究进展[J/CD]. 中华医学超声杂志(电子版), 2017, 14(1): 8-10.
[13]
田鹏, 房世保, 杜文燕, 等. 超声组织弹性成像对四肢深静脉血栓分期诊断的临床价值[J]. 滨州医学院学报, 2014, 37(1): 24-27.
[14]
邹斌, 曾福强, 邵菲, 等. 超声弹性成像评估股浅静脉血栓形成在时间分期中的应用价值[J]. 国际医药卫生导报, 2016, 22(6): 750-752.
[15]
Liu X,Li N,Wen C. Effect of pathological heterogeneity on shear wave elasticity imaging in the staging of deep venous thrombosis[J]. PLoS One, 2017, 14(6): 1-15.
[1] 江宇轩, 刘文丽, 武会娟, 方晨, 钱嘉林. 神经动态超声弹性成像的三维有限元分析[J]. 中华医学超声杂志(电子版), 2021, 18(06): 583-589.
[2] 张君, 沈素红, 刘春龙, 张志杰. 剪切波弹性成像技术量化评估健康人斜方肌弹性模量的应用[J]. 中华医学超声杂志(电子版), 2021, 18(03): 307-312.
[3] 任玲, 罗渝昆, 宋青, 费翔, 田晓琦, 焦子育. 超声造影及弹性成像技术对超声造影无增强甲状腺结节良恶性的鉴别诊断价值[J]. 中华医学超声杂志(电子版), 2020, 17(06): 552-557.
[4] 张会萍, 周毓青. 乳腺癌超声弹性诊断新进展[J]. 中华乳腺病杂志(电子版), 2021, 15(01): 1-3.
[5] 强坤坤, 罗红. 杜氏肌营养不良症患儿的高频超声与剪切波弹性成像诊断研究现状及前景[J]. 中华妇幼临床医学杂志(电子版), 2023, 19(02): 162-167.
[6] 吴金柱, 蔡卫华, 徐磊, 陈琳, 肖锋, 许甜, 王建新, 朱任飞, 季汉珍, 张鹏. 标准残肝体积联合瞬时弹性成像技术预测半肝切除的安全性研究[J]. 中华普外科手术学杂志(电子版), 2020, 14(06): 585-589.
[7] 张健, 林俊, 沈洪亮, 刘志佳, 张东兴, 吴巍巍, 王强. 自体大隐静脉逆转替代肾动脉或肾静脉自体肾移植二例[J]. 中华移植杂志(电子版), 2021, 15(02): 101-104.
[8] 狄金明, 黄展森, 吴杰英, 黄群雄, 王华, 李腾成, 罗云. 全腹腔镜下左肾静脉移位术治疗胡桃夹综合征[J]. 中华腔镜泌尿外科杂志(电子版), 2022, 16(04): 375-376.
[9] 狄金明, 黄展森, 吴杰英, 黄群雄, 王华, 李腾成, 罗云. 机器人辅助腹腔镜下左肾静脉移位术治疗胡桃夹综合征[J]. 中华腔镜泌尿外科杂志(电子版), 2022, 16(04): 373-374.
[10] 崔宁宜, 王勇, 唐源, 张蕊, 刘孟嘉. 直肠腔内剪切波弹性成像对局部进展期直肠癌新辅助放化疗后T分期的价值[J]. 中华结直肠疾病电子杂志, 2020, 09(06): 586-591.
[11] 李玉龙, 焦龙兵, 郑连生. 液氮冷冻法制备兔股骨头坏死模型新方法及效果评估[J]. 中华老年骨科与康复电子杂志, 2022, 08(05): 263-268.
[12] 马宁, 刘雨丰, 陈明学, 王月香, 万一群, 刘舒云, 眭翔, 郭全义. 仿生组织工程软骨修复关节软骨损伤的效果及应用超声弹性成像方法检测价值分析[J]. 中华老年骨科与康复电子杂志, 2020, 06(02): 62-67.
[13] 刘新献, 王雅琪, 周斌, 郭严延. 雷帕霉素在兔腐蚀性食管炎性狭窄早期干预中的意义[J]. 中华介入放射学电子杂志, 2023, 11(04): 324-329.
[14] 李世凯, 梁佳, 何艳艳, 于毅, 李天晓, 常金龙, 贺迎坤. 兔颈动脉粥样硬化性狭窄模型在介入治疗的应用进展[J]. 中华介入放射学电子杂志, 2023, 11(04): 357-362.
[15] 杨斌, 侯曼曼, 王少春. 高频超声及弹性成像技术对周围神经病变诊断价值的研究进展[J]. 中华诊断学电子杂志, 2020, 08(02): 141-144.
阅读次数
全文


摘要