Chinese Journal of Medical Ultrasound (Electronic Edition) ›› 2021, Vol. 18 ›› Issue (09): 862-867. doi: 10.3877/cma.j.issn.1672-6448.2021.09.009

• Interventional Ultrasound • Previous Articles     Next Articles

Value of endobronchial ultrasound with guide-sheath in diagnosis of benign and malignant lung diseases

Yukun Fang1, Jia Song1, Yu Li1, Jian Wang1, Qingyong Chen1,()   

  1. 1. Department of Respiratory and Critical Care Medicine, PLA 903 Hospital, Hangzhou 31000, China
  • Received:2020-03-21 Online:2021-09-01 Published:2021-09-30
  • Contact: Qingyong Chen

Abstract:

Objective

To assess the value of endobronchial ultrasound with guide-sheath (EBUS-GS) in the diagnosis of benign and malignant lung diseases.

Methods

A retrospective analysis was performed on the clinical data and test results of 154 patients with lung lesions who underwent routine EBUS-GS at the PLA 903 Hospital from January 2018 to June 2019. Using the pathological diagnosis as the gold standard, a four-fold table was used to calculate the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of EBUS-GS in the diagnosis of benign and malignant lung lesions. The χ2 test and two-class Logistic regression were used to assess the value of EBUS-GS characteristics in the prediction of malignancy of lung diseases.

Results

Among the 154 patients who underwent EBUS-GS examination, 96 had benign lesions, 54 had malignant lesions, and 4 had lesions whose nature was unclear. According to the gold standard of pathological diagnosis, the accuracy of EBUS-GS was 98.05% (151/154), the consistency rate with the pathology diagnosis was 90.26% (139/154), the sensitivity was 88.42% (84/95), the specificity was 98.15% (53/54), the positive predictive value was 98.82% (84/85), and the negative predictive value was 82.81% (53/64). On EBUS-GS, malignant lesions mostly had an irregular shape, unclear and discontinuous boundary, and basically uniform echo; the interior of the lesions mostly exhibited clumpy-like low echo and some dot-like high echo in the tissue containing gas. In contrast, benign lesions mostly had a regular (round or oval-based) shape, clear and continuous boundary, and mostly uneven echo; the interior of the lesions manily exhibited high echo, with most showing dot or spot-shaped high echo. Logistic regression analysis demonstrated that the acoustic characteristics of EBUS-GS were of some value to predict malignant diseases in the lungs (P<0.05).

Conclusion

EBUS-GS has appreciated value in the diagnosis of benign and malignant lung diseases, which is helpful for the preliminary evaluation of benign and malignant lung diseases and can provide a new basis for the early clinical diagnosis in the future.

Key words: Ultrasound, endobronchial, Guide-sheath, Lung, cancer, Differential diagnosis