Chinese Journal of Medical Ultrasound (Electronic Edition) ›› 2016, Vol. 13 ›› Issue (12): 911-917. doi: 10.3877/cma.j.jssn.2095-5820.2016.12.008

Special Issue:

• Superficial Parts Ultrasound • Previous Articles     Next Articles

Value of contrast enhanced ultrasound combined with elastography in differential diagnosis of thyroid imaging reporting and data system 4 thyroid nodules

Huijuan Ma1, Jingchun Yang1,(), Zhenpeng Leng1, Jia Ma1, Hua Kang2, Lianghong Teng3   

  1. 1. Department of Ultrasound, Xuanwu Hospital, Capital Medical University, Beijing 100053, China
    2. Department of Surgery, Xuanwu Hospital, Capital Medical University, Beijing 100053, China
    3. Department of Pathology, Xuanwu Hospital, Capital Medical University, Beijing 100053, China
  • Received:2015-05-24 Online:2016-12-01 Published:2016-12-01
  • Contact: Jingchun Yang
  • About author:
    Corresponding author: Yang Jingchun, Email:

Abstract:

Objective

To assess the diagnostic value of contrast enhanced ultrasound (CEUS), elastography and their combined use in diagnosing thyroid nodules of thyroid imaging reporting and data system (TI-RADS) 4.

Methods

From November 2011 to August 2016, 159 TI-RADS 4 nodules diagnosed by conventional ultrasound were prospectively enrolled and examined by CEUS and elastography before surgery. Multivariate logistic regression models were established for CEUS and CEUS combined with elastography to diagnose thyroid malignancy. The diagnostic performances of CEUS, elastography and their combined use were evaluated with the receiver operating characteristic (ROC) curve. The sensitivity, specificity, accuracy, positive predictive value, negative predictive value and omission diagnostic rate of CEUS, elastography and their combined use were compared by Chi-square test.

Results

The CEUS features significantly predicting malignancy were heterogeneous enhancement, hypoenhancement, without or incomplete ring-enhancement and later time to peak than the surrounding parenchyma (χ2=24.378, 69.194, 29.434 and 7.375, all P<0.01). Furthermore, the multivariate logistic regression for CEUS combined with elastography showed that heterogeneous enhancement, ring enhancement and elasticity score were the independent predictors of thyroid malignancy. The area under the ROC curve of CEUS combined with elastography was (0.921±0.023) which was higher than that of CEUS and elatography (0.88±0.029 and 0.80±0.038, respectively; both P<0.05). Moreover, the sensitivity, accuracy and negative predictive value of CEUS combined with elastography were 92.1%, 86.2% and 84.6%, respectively. The omission diagnostic rate of CEUS combined with elastography (7.9%) was reduced. And the diagnostic accuracy of CEUS combined with elastography was significantly higher than that of CEUS and elastography (P<0.05). While the diagnostic accuracy of CEUS was close to the elastography, the difference was not statistically significant (P>0.05).

Conclusion

The diagnostic value of CEUS combined with elastography was remarkably significant in the differential diagnosis of TI-RADS 4 nodules.

Key words: Ultrasonography, Elasticity imaging techniques, Thyroid nodule