Application of model for improvement in preoperative diagnosis of breast lesions by ultrasound

Li Ma1, Jing Qin1, Qingli Zhu1,(), He Liu1, Jing Zhang1, Mengsu Xiao1, Hongyan Wang1, Jianchu Li1, Yuxin Jiang1   

  1. 1. Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing 100730, China
  • Received:2020-05-09 Online:2021-04-01 Published:2021-05-08
  • Contact: Qingli Zhu

Abstract:

Objective

To explore the application of the Model for Improvement (MFI) in the procedure of preoperative diagnosis of breast ultrasound.

Methods

Consecutive patients with breast lesions who had a preoperative diagnosis by breast ultrasound were divided into either a study group (50 patients, from July to October 2019) or a control group (50 patients, from January to April 2019). In the study group, MFI was developed and used, which involved a series of actions such as on-site review by specialized doctors, training enhancement of specialized doctors, improvement of appointment procedures, etc. In the control group, no intervention was performed. The diagnostic accuracy rate, rate of undetermined diagnosis, appointment time, and number of hospital visits were compared between two groups.

Results

The diagnostic accuracy rates of the study and control groups were 91.7% and 70.5%, and the rates of undetermined diagnosis were 4.0% and 12.0%, respectively, with significantly statistical differences between the two groups (P<0.05). The appointment time of the study and control group was (0.58±0.99) days and (5.76±2.35) days, and the number of hospital visits was 1.38±0.63 and 2.52±0.67, respectively, with significantly statistical differences between the two groups (P<0.05).

Conclusion

MFI can optimize the procedure of preoperative diagnosis of breast ultrasound, make full use of the limited medical resources, and benefit more patients.

Key words: Breast neoplasms, Ultrasonography, Model for improvement, PDSA cycle

Copyright © Chinese Journal of Medical Ultrasound (Electronic Edition), All Rights Reserved.
Tel: 010-51322630、2632、2628 Fax: 010-51322630 E-mail: csbjb@cma.org.cn