Home    中文  
 
  • Search
  • lucene Search
  • Citation
  • Fig/Tab
  • Adv Search
Just Accepted  |  Current Issue  |  Archive  |  Featured Articles  |  Most Read  |  Most Download  |  Most Cited

Chinese Journal of Medical Ultrasound (Electronic Edition) ›› 2018, Vol. 15 ›› Issue (12): 919-924. doi: 10.3877/cma.j.issn.1672-6448.2018.12.007

Special Issue:

• Obstetric and Gynecologic Ultrasound • Previous Articles     Next Articles

Quantitative assessment of fetal cardiac axis changes in normal fetuses and fetuses with congenital heart disease

Jinshuang Zhang1, Bowen Zhao2,(), Ruyan Tan2, Bei Wang2, Mei Pan2, Xiaohui Peng2, Ran Chen2   

  1. 1. Department of Diagnostic Ultrasound & Echocardiography, Sir Run Run Shaw Hospital, Zhejiang University College of Medicine, Technical Guidance Center for Fetal Echocardiography of Zhejiang Province & Sir Run Run Shaw Institute of Clinical Medicine of Zhejiang University, Hangzhou 310016, China
  • Received:2018-06-14 Online:2018-12-01 Published:2018-12-01
  • Contact: Bowen Zhao
  • About author:
    Corresponding author: Zhao Bowen, Email:

Abstract:

Objective

To investigate the cardiac axis changes within the cardiac cycle of both normal fetuses and fetuses with congenital heart diseases (CHD), and construct reference range of cardiac axis for normal fetuses.

Methods

Two hundred sixty-five fetuses were enrolled in our study, of whom 197 were normal fetuses and 68 were fetuses with CHD. The cardiac axis was measured at end systole (CAS°) and at end diastole (CAD°) in each case. Subsequently, all parameters were compared between the normal and CHD groups. The independent t-test was used to compare CAS° and CAD° parameters between the healthy control group and the middle pregnancy group and the late pregnancy group, and between the healthy control group and the CHD group. According to the practice guideline the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG): the normal reference range for normal fetal cardiac axis was (45±20)°, with<25° and/or>65° defined as abnormal fetal cardiac axis. The Chi-square test was used to compare the proportion of CAS° and CAD° CA abnormalities between the healthy control group and the CHD group.

Results

No significant difference was observed in comparison of maternal age and gestational age between 197 healthy controls and 68 CHD controls (P>0.05). There was no significant difference between CAS° and CAD° of the fetus in the healthy control group with the increase of the second and third gestational weeks (P>0.05). The mean cardiac axis in control group was (40.88±10.27)° at end systole, and (35.07±9.44)° at end diastole, resulting in an average difference of (5.85±4.42)°. While the mean cardiac axis in fetuses with CHD was (44.34±15.03)° at end systole and (41.32±16.71)° at end diastole, resulting in an average difference of (5.01±3.52)°. Significant difference was observed between two groups (t=-2.11,-3.79, all P<0.05). Among 197 normal cases, there were 11 cases with abnormal CAS° (4 cases with decreased CAS° and 7 cases with increased CAS°) accounting for 5.6%. There were 27 cases with abnormal CAD° (26 cases with decreased CAD° and 1 case with increased CAD°), accounting for 13.7%. In 68 CHD cases, there were 10 cases with abnormal CAS° (4 cases with decreased CAS° and 6 cases with increased CAS°) accounting for 14.7%. There were 17 cases with abnormal CAD° (12 cases with decreased CAD° and 5 cases with increased CAD°) accounting for 25.0%. The abnormity rates of both CAS° and CAD° were significantly lower in normal group than in the CHD group. The difference was statistically significant (χ2=5.765, 4.657, all P<0.05).

Conclusions

Measurement of cardiac axis at end systole and at end diastole provides values in screening for fetuses with congenital heart disease, and can be used as a routine measurement tool.

Key words: Heart disease, Fetus, Ultrasonography

Copyright © Chinese Journal of Medical Ultrasound (Electronic Edition), All Rights Reserved.
Tel: 010-51322630、2632、2628 Fax: 010-51322630 E-mail: csbjb@cma.org.cn
Powered by Beijing Magtech Co. Ltd