中华医学超声杂志(电子版) ›› 2020, Vol. 17 ›› Issue (07) : 667 -671. doi: 10.3877/cma.j.issn.1672-6448.2020.07.015

所属专题: 超声医学质量控制 文献

超声医学质量控制

用累积和控制图建立早孕期胎儿颈项透明层厚度测量的质控体系
杨昕1, 李志辉1, 韩瑾1, 甄理1, 潘敏1, 李东至1, 廖灿1,()   
  1. 1. 510623 广州市妇女儿童医疗中心产前诊断门诊
  • 收稿日期:2020-04-28 出版日期:2020-07-01
  • 通信作者: 廖灿

Cumulative sum plots in first-trimester nuchal translucency quality assurance

Xin Yang1, Zhihui Li1, Jin Han1, Li Zhen1, Min Pan1, Dognzhi Li1, Can Liao1,()   

  1. 1. Guangzhou Women and Children Hospital, Prenatal Diagnosis Center, Guangzhou 510623, China
  • Received:2020-04-28 Published:2020-07-01
  • Corresponding author: Can Liao
  • About author:
    Corresponding author: Liao Can, Email:
引用本文:

杨昕, 李志辉, 韩瑾, 甄理, 潘敏, 李东至, 廖灿. 用累积和控制图建立早孕期胎儿颈项透明层厚度测量的质控体系[J]. 中华医学超声杂志(电子版), 2020, 17(07): 667-671.

Xin Yang, Zhihui Li, Jin Han, Li Zhen, Min Pan, Dognzhi Li, Can Liao. Cumulative sum plots in first-trimester nuchal translucency quality assurance[J]. Chinese Journal of Medical Ultrasound (Electronic Edition), 2020, 17(07): 667-671.

目的

采用累积和控制图(CUSUM)对早孕期胎儿颈项透明层厚度(nuchal translucency,NT)的测量值进行质控分析,建立NT测量的质控体系。

方法

选取2018年1月至2019年1月广州市妇女儿童医疗中心以中国南方人群的胎儿NT中位数值作为参考,将本中心的NT测量值转换为NT中位数倍数值(MoM值),计算每位操作者每天的NT MoM值的中位数和SD值,用CUSUM控制图建立NT测量质控系统。对一位经验丰富的超声医师近20 d的NT测量数据进行评估,将失控的病例与在控病例进行比较分析,检验本质控体系的有效性。从第一位超声医师的NT测量数据中,选取累积和(cumulative sum)为0的该日的所有NT数据,人为的将该日所有NT值±1.0 mm及±0.5 mm,进行CUSUM质控分析,检验质控体系的有效性。采用本质控系统对1位初学者的NT测量结果进行分析,并将所有入组NT图像进行评分,验证CUSUM控制图的有效性。不同组NT图像评分结果之间的比较采用χ2检验。

结果

本中心早孕期胎儿NT MoM的中位值为1.1 MoM,SD为0.23 MoM,建立CUSUM控制图。对1位经验丰富的超声医师的近20 d的NT测量结果进行质控分析,结果提示第8、13天的NT测量值出现明显偏倚,通过对这2 d所有的NT图像进行评分,发现图像满意率仅38.9%和40%。当NT测量数值误差超过±1.0 mm时,本CUSUM控制图可以发现数据偏倚。对第2位超声医师的数据进行质控分析,发现数值明显偏小,此结果与图像评分结果一致。

结论

CUSUM控制图对NT测量质量进行评估是有效的超声质控方法。

Objective

To evaluate the quality assurance of fetal nuchal translucency (NT) in the first trimester by cumulative sum (CUSUM) plots.

Methods

Based on the reference range of median NT, the median of the NT MoM distribution and standard deviation (SD) were determined. CUSUM plots were created to assess whether there was an over- or under-estimation of NT measurement for each sonographer. An NT image scoring system was established to testify the results analyzed by CUSUM plots.

Results

The median NT MoM at our center was 1.1 mm, and SD was 0.23mm. CUSUM plots were created for NT assessment. For an experienced sonographer, 20 days of NT measurement were included for CUSUM scoring, which showed that NT on days 8 and 13 was overestimated. We then investigated all the NT images on these two days by the NT image scoring system, and the result was in agreement with CUSUM plots. When the measurement error of NT was above 1.0 mm, the median NT MoM lied outside the accepted limits by CUSUM plots. For a beginner sonographer, the results obtained by CUSUM plotswere quite similar to those obtained by the image scoring system.

Conclusion

The application of cumulative sum plots in quality assurance of nuchal translucency measurement is acceptable.

图1 胎儿颈项透明层厚度测量的累积和控制图分析
表1 2位超声医师的NT测量质量评分列表
1
Nicolaides KH, Azar G, Byrne D, et al. Fetal nuchal translucency: ultrasound screening for chromosomal defects in first trimester of pregnancy [J]. BMJ, 1992, 304(6831): 867-869.
2
Taipale P, Hiilesmaa V, Salonen R, et al. Increased nuchal translucency as a marker for fetal chromosomal defects [J]. New Engl J Med, 1997, 337(23): 1654-1658.
3
Snijders RJ, Noble P, Sebire N, et al. UK multicentre project on assessment of risk of trisomy 21 by maternal age and fetal nuchal translucency thickness at 10-14weeks of gestation [J]. Lancet, 1998, 352(9125): 343-346.
4
Kagan KO, Wright D, Etchegaray A, et al. Effect of deviation of nuchal translucency measurements on the performance of screening for trisomy 21 [J]. Ultrasound Obstet Gynecol, 2009, 33(6): 657-664.
5
Snijders RJ, Thom EA, Zachary JM, et al. First-trimester trisomy screening: nuchal translucency measurement training and quality assurance to correct and unify technique [J]. Ultrasound Obstet Gynecol, 2002, 19(4): 353-359.
6
Sahota DS, Leung WC, To WK et al. Quality assurance of nuchal translucency for prenatal fetal Down syndrome screening [J]. J Matern Fetal Neonatal Med, 2012, 25(7): 1039-1043.
[1] 武玺宁, 欧阳云淑, 张一休, 孟华, 徐钟慧, 张培培, 吕珂. 胎儿心脏超声检查在抗SSA/Ro-SSB/La抗体阳性妊娠管理中的应用[J]. 中华医学超声杂志(电子版), 2023, 20(10): 1056-1060.
[2] 杨水华, 何桂丹, 覃桂灿, 梁蒙凤, 罗艳合, 李雪芹, 唐娟松. 胎儿孤立性完全型肺静脉异位引流的超声心动图特征及高分辨率血流联合时间-空间相关成像的应用[J]. 中华医学超声杂志(电子版), 2023, 20(10): 1061-1067.
[3] 赵红娟, 赵博文, 潘美, 纪园园, 彭晓慧, 陈冉. 应用多普勒超声定量分析正常中晚孕期胎儿左心室收缩舒张时间指数[J]. 中华医学超声杂志(电子版), 2023, 20(09): 951-958.
[4] 张璟璟, 赵博文, 潘美, 彭晓慧, 毛彦恺, 潘陈可, 朱玲艳, 朱琳琳, 蓝秋晔. 胎儿超声心动图测量McGoon指数在评价胎儿肺血管发育中的应用[J]. 中华医学超声杂志(电子版), 2023, 20(08): 860-865.
[5] 旺久, 陈军, 朱霞, 米玛央金, 赵胜, 陈欣林, 李建华, 王双. 山南市妇幼保健院开展胎儿系统超声筛查的效果分析[J]. 中华医学超声杂志(电子版), 2023, 20(07): 728-733.
[6] 徐鹏, 李军, 高巍伦, 王峥, 庞珅, 李春妮, 朱霆. 快速旋转扫查法在胎儿超声心动图检查中的应用价值[J]. 中华医学超声杂志(电子版), 2023, 20(07): 761-766.
[7] 谭芳, 杨娇娇, 沈玉琴, 李炎菲海, 王海蕊, 范思涵, 纪学芹. 胎儿心脏定量分析技术对正常胎儿心脏形态及收缩功能的评价[J]. 中华医学超声杂志(电子版), 2023, 20(06): 598-604.
[8] 罗刚, 泮思林, 陈涛涛, 许茜, 纪志娴, 王思宝, 孙玲玉. 超声心动图在胎儿心脏介入治疗室间隔完整的肺动脉闭锁中的应用[J]. 中华医学超声杂志(电子版), 2023, 20(06): 605-609.
[9] 黄佳, 石华, 张玉国, 胡佳琪, 陈茜. 胎儿左头臂静脉正常与异常超声图像特征及其临床意义[J]. 中华医学超声杂志(电子版), 2023, 20(06): 610-617.
[10] 袁泽, 庄丽. 超声检测胎儿脐动脉和大脑中动脉血流对胎儿宫内窘迫的诊断价值[J]. 中华医学超声杂志(电子版), 2023, 20(06): 618-621.
[11] 刘镭, 杨昕, 许晓华, 林胜谋, 熊初琴, 农丽录, 董振宇, 李胜利. 中孕期胎儿鼻前皮肤厚度及鼻骨长度筛查胎儿染色体病的临床价值[J]. 中华医学超声杂志(电子版), 2023, 20(05): 506-510.
[12] 李博, 孔德璇, 彭芳华, 吴文瑛. 超声在胎儿肺静脉异位引流诊断中的应用价值[J]. 中华医学超声杂志(电子版), 2023, 20(04): 437-441.
[13] 薛超, 张烨, 赵映, 韩建成, 谷孝艳, 孙琳, 刘晓伟, 宋伟, 何怡华. 胎儿先天性肺动脉瓣缺如综合征的超声特征及预后分析[J]. 中华妇幼临床医学杂志(电子版), 2023, 19(04): 410-418.
[14] 刘磊, 王优, 黄锐斌, 张丽娜, 宋一丹, 雷婷缨. 染色体微阵列分析技术在股骨长度偏短胎儿遗传学诊断中的应用[J]. 中华妇幼临床医学杂志(电子版), 2023, 19(04): 437-445.
[15] 邹艳丽, 栾文杰, 王淑娟, 刘亚琴, 初桂芝, 李松洋, 王好玲, 张锦婷, 姜鑫, 栾泽东. 早孕期胎儿右位主动脉弓的产前超声诊断学特征[J]. 中华诊断学电子杂志, 2023, 11(04): 227-232.
阅读次数
全文


摘要